Firewood Cord Calculator
Firewood Measurement Engine • Firewood Cord Calculator

Firewood Cord Calculator

Instant Wood Volume Engine

Firewood Cord Calculator

Calculate standard cords, face cords, truckload volume, and estimated firewood heating costs.

Presets:

Stack Measurements Imperial (Feet & Inches)

ft
in
1 ft 10 ft 20 ft 40 ft
ft
in
8 in 16 in (Face Cord) 4 ft (Standard) 12 ft
ft
in
1 ft 4 ft (Standard) 6 ft 12 ft

Accounts for natural airspace between split logs

85% (Typical split)
50% (Loose Thrown) 70% (Rough) 85% (Standard Split) 100% (Solid Wood)

Price & Delivery Cost Estimator Optional

$
$
$
Estimated Total Cost
$350.00
Wood: $300.00
Delivery & Stacking: $50.00
Face Cord Equiv: ~$116.67
Calculated Wood Volume 128 ft³ / Cord
Standard Cords
1.00 Full Cords
Gross Volume: 128.00 ft³
Metric Equivalent: 3.62 m³ (Stère)
Solid Wood Content: ~108.8 ft³ (85%)
Face Cords
3.00
@ 16" split
Half Cords
2.00
@ 64 ft³
Ricks / 1/4
4.00
@ 32 ft³
Front View Stack Diagram 8.0' L × 4.0' H
Split round logs ~32 visible logs

Saved Stack Comparisons 0

Save multiple wood stacks to compare volume, cord fractions, and prices.

No saved stacks yet

Adjust dimensions and click "Save Stack Calculation" above to compare multiple piles.

Complete Calculation Suite

Specialized Firewood Calculators & Tools

Choose from our suite of precision calculators for accurate timber measurements, conversions, and delivery planning.

128 ft³ Standard

Full Cord Calculator

Standard 128 cu ft cord calculator with 3D stack visualizer, fraction converter, and cost estimator.

Currently Active Tool
Single Row

Face Cord Calculator

Calculate exact face cords for 12, 16, 18, and 24-inch log lengths and compare against full cords.

Bulk / Dumped

Loose Cord Calculator

Convert dumped, tossed, or trailer-delivered bulk firewood into tightly stacked cord volume.

Multi-Unit

Cord to Cubic Feet Converter

Two-way converter between cords, cubic feet (ft³), cubic meters (m³ / stère), and ricks.

Lbs & Tons

Cord Weight Calculator

Estimate green and seasoned wood weight by species (Oak, Maple, Pine) with truck payload warnings.

32 ft³ Rick

Quarter Cord (1/4) Calculator

Calculate 32 cu ft stack dimensions, rick equivalents, and check pickup truck bed capacity fit.

Measurement Methodology

How Firewood Cord Calculation Works

North American legal measurement standards (NIST Handbook 130), stacking density, and official volume formulas

1

Measure Tightly Stacked Dimensions

Under United States Weights & Measures standards, firewood must be measured stacked tightly in parallel rows with end support posts—never loose thrown in a truck bed.

2

Compute Gross Stack Volume (ft³ or m³)

Multiply stack length × height × log cut depth. A legal standard cord requires 128 gross cubic feet (or 3.62 m³ metric stère), enclosing ~85 ft³ of solid wood timber.

3

Verify Cords, Moisture & Energy Output

Divide total cubic feet by 128. Verify seasoning with an EPA Burn Wise digital pin moisture meter (<20% moisture) to ensure peak wood stove BTU efficiency and prevent flue creosote.

Standard Conversion Benchmarks

Standard Firewood Cord Reference Chart

Comparison of official firewood measurement units, stack dimensions, cubic volume, and estimated heating duration.

Measurement Unit Dimensions (H × W × L) Cubic Feet Cubic Meters Cord Equivalent
Full Standard Cord Popular
Official Legal Standard
4 ft × 4 ft × 8 ft
1.22 m × 1.22 m × 2.44 m
128 ft³ 3.62 m³ (Stère) 6–10 weeks (Full Winter Primary Heat)
Half Cord
Standard Half Stack
4 ft × 4 ft × 4 ft
1.22 m × 1.22 m × 1.22 m
64 ft³ 1.81 m³ 3–5 weeks (Moderate Supplemental Heat)
Face Cord (16" Logs) Popular
Most Common Retail Unit
4 ft × 1.33 ft × 8 ft
1.22 m × 0.40 m × 2.44 m
42.67 ft³ 1.21 m³ 2–3 weeks (Fireplace & Evening Use)
Quarter Cord / Rick
Small Batch / Campfire
4 ft × 2 ft × 4 ft (or 1/4 Cord)
1.22 m × 0.61 m × 1.22 m
32 ft³ 0.91 m³ 1–2 weeks (Occasional Weekend Burning)
Double Cord
Bulk Winter Supply
4 ft × 8 ft × 8 ft (or 4 × 4 × 16 ft)
1.22 m × 2.44 m × 2.44 m
256 ft³ 7.25 m³ Entire Season (Large Rural Home)

• Note: Solid wood content ranges from 75–90 cu ft per standard cord due to natural air spaces between split logs.

Test your custom stack in the calculator →
Domain Knowledge & Taxonomy

Key Firewood Measurement & Heating Entities

Authoritative physical definitions, volumetric conversion baselines, and thermal energy metrics.

Legal Standard Unit 4 ft × 4 ft × 8 ft
Full Cord (128 ft³ / 3.62 m³)
The legal standard unit of stacked firewood in North America, legally defined by NIST Handbook 130 and the USDA Forest Service as 128 gross cubic feet (3.62 m³ in metric stère). When split logs are tightly stacked, a full cord typically yields between 75 and 90 ft³ of solid wood volume, with the remaining 38 to 53 ft³ consisting of interstitial airspace necessary for airflow.
Retail Fraction Unit 4 ft × 1.33 ft (16") × 8 ft
Face Cord / Rick (42.67 ft³)
A widely used retail and residential measurement representing a single vertical tier of firewood measuring 4 feet high by 8 feet long, cut to standard 16-inch stove lengths (1.33 ft). One face cord yields approximately 42.67 cubic feet—precisely one-third (1/3) of a standard 128 ft³ full cord. In regional markets, this volume is also referred to as a "rick" or "fireplace cord".
Fuel Density & Coals 24.0–28.0+ Million BTU/Cord
Hardwood Species (High BTU Yield)
Dense, slow-growing deciduous trees with compact cellular vascular systems. Premier heating hardwoods—including White Oak (25.7M BTU), Sugar Maple (24.0M BTU), and Shagbark Hickory (27.7M BTU)—generate sustained, high-temperature heat output and long-lasting ember beds that sustain overnight home heating with minimal reloading.
Fast Ignition & Flame 15.0–20.0 Million BTU/Cord
Softwood Species (Kindling & Shoulder Seasons)
Coniferous gymnosperms including White Pine (15.9M BTU), Douglas Fir (20.6M BTU), and Spruce. Softwoods feature lower specific gravity and resinous fibers that ignite rapidly and burn with brisk flame. They are ideal for lighting kindling, rapid stove warm-up, and moderate autumn or spring temperatures where intense long-burning coal beds are unnecessary.
Thermal Energy Metric 1 BTU = Heat to raise 1 lb H₂O by 1°F
British Thermal Unit (BTU Heat Output)
The international physical standard used to quantify the chemical heat energy released during wood combustion. In firewood calculations, heat output is evaluated in Millions of BTUs (MBTU) per air-dried cord at 20% moisture content, directly reflecting dry wood density rather than species volume alone.
Combustion Efficiency Standard Moisture Content < 20% (Dry Basis)
Seasoned Wood (<20% Moisture Content)
Firewood that has been split, elevated off damp ground, and naturally seasoned in breezy sun exposure for 6 to 24 months. Burning wood with under 20% moisture ensures heat is radiated into living spaces rather than wasted evaporating internal sap water, reducing creosote condensation and chimney fire hazards by over 90% in accordance with CSIA and NFPA 211 guidelines.
Heating Appliance Efficiency EPA Certified 70–80%+ Efficiency
Wood-Burning Stove (EPA Clean Burn)
Modern airtight wood-burning stoves and fireplace inserts engineered with secondary combustion air tubes or catalytic combustors. Operating an EPA-certified stove with properly measured, dry hardwood produces minimal particulate emissions, delivers clean burn cycles, and extracts maximum BTUs per cord compared to open masonry hearths.
Diagnostic Testing Tool Electrical Resistance Pin Gauge
Digital Pin Moisture Meter
The authoritative diagnostic tool recommended by the EPA Burn Wise initiative and USDA Forest Service. By penetrating two metal probe pins into the freshly split center grain of a log, home heating operators verify whether wood has achieved the safe threshold of under 20% moisture content prior to burning.
Processing & Curing Tool 20–35 Ton Splitting Force
Hydraulic Log Splitter
Heavy-duty machinery that divides round logs into triangular or rectangular splits. Because intact tree bark acts as a natural water-repellent vapor barrier, mechanical log splitting multiplies exposed surface area by up to 400%, allowing internal sap moisture to evaporate rapidly during summer seasoning.
Expert Answers

Frequently Asked Questions

Everything you need to know about firewood cord measurements, legal definitions, and stacking

What is the legal definition of a standard cord of firewood in the United States?

Under National Institute of Standards and Technology (NIST) Handbook 130 and United States state weights and measures laws, a legal cord of firewood is strictly defined as 128 gross cubic feet of tightly ranked, parallel-stacked wood. The standard reference stack measures 4 feet high by 4 feet deep by 8 feet long (4' × 4' × 8'). Most states legally prohibit vendors from selling bulk firewood using vague terms such as 'truckload', 'pile', 'rack', or 'unit' without clearly stating the exact cord or cubic-foot equivalent.

What is the difference between a full cord and a face cord (rick)?

A full cord is a volumetric standard of 128 cubic feet (48" deep). A face cord (frequently called a 'rick' or 'fireplace cord' across the Midwest and Southern US) is a single stack that is 4 feet high and 8 feet long, but only one log deep. When cut to the standard 16-inch stove length (1.33 ft), a face cord measures 42.67 cubic feet—exactly one-third (1/3) of a full cord. Three 16-inch face cords stacked side-by-side equal one full cord.

How do I test firewood moisture content using a digital moisture meter?

The EPA Burn Wise program and USDA Forest Service recommend using a two-pin digital wood moisture meter. To test accurately: split a seasoned log lengthwise right before testing, press the meter pins firmly into the freshly exposed center grain parallel to the wood fibers, and read the percentage. Seasoned firewood ready for clean burning must read below 20% wood moisture content (WMC). Fresh 'green' firewood often tests between 45% and 60% moisture.

Why is burning green or wet firewood hazardous to chimneys and wood stoves?

According to the Chimney Safety Institute of America (CSIA) and National Fire Protection Association (NFPA 211), unseasoned wood with over 20% moisture wastes up to 50% of its combustion energy boiling away internal water. This cool, smoldering burn generates excessive unburned volatile hydrocarbons that condense inside the flue chimney pipe as Stage 3 glazed creosote—the leading primary cause of violent chimney fires.

How much firewood fits in a standard pickup truck bed?

A standard 8-foot longbed pickup truck holds roughly 1/2 of a cord (64 cubic feet stacked) level with the bed rails, or about 1/3 cord if tossed loose. A 6.5-foot shortbed holds approximately 1/3 cord neatly stacked (~42.7 ft³) or 1/4 cord thrown. A 5.5-foot crew cab bed fits roughly 1/4 cord (32 ft³). Beware of payload limits: a full cord of seasoned Oak weighs over 4,000 lbs, requiring a 1-ton truck or heavy tandem trailer.

How does using a hydraulic log splitter speed up firewood drying?

Arborists and forestry experts advise splitting round logs immediately with a hydraulic log splitter or splitting maul rather than seasoning logs in the round. Tree bark acts as a waterproof vapor barrier; splitting exposes internal capillary vessels to sun and cross-breeze airflow, accelerating seasoning time from 2–3 years down to 6–12 months for dense hardwoods like White Oak and Sugar Maple.

How much solid wood is inside a 128 cubic foot cord?

Because split logs possess natural curvature and irregular bark edges, a 128 cubic foot cord contains approximately 75 to 90 cubic feet of actual solid wood fiber (with 85 cu ft as the standard forestry benchmark). The remaining 38 to 53 cubic feet consists of necessary interstitial airspace that permits healthy air circulation and continuous seasoning in the woodpile.

Which firewood species produce the highest heat output (BTU) for wood stoves?

Dense hardwoods generate the greatest thermal energy per cord: Shagbark Hickory (27.7 Million BTU), White Oak (25.7M BTU), Sugar Maple (24.0M BTU), and White Ash (23.6M BTU). Softwoods like Eastern White Pine (15.9M BTU) and Douglas Fir (20.6M BTU) produce lower heat but ignite quickly, making them ideal kindling for modern high-efficiency EPA-certified wood-burning stoves.