Firewood Cord Calculator
Vedmätningsmotor • Firewood Cord Calculator

Accurate Firewood Cord Calculations Made Simple

Instant Wood Volume Engine

Firewood Cord Calculator

Calculate standard cords, face cords, truckload volume, and estimated firewood heating costs.

Presets:

Stack Measurements Imperial (Feet & Inches)

ft
in
1 ft 10 ft 20 ft 40 ft
ft
in
8 in 16 in (Face Cord) 4 ft (Standard) 12 ft
ft
in
1 ft 4 ft (Standard) 6 ft 12 ft

Accounts for natural airspace between split logs

85% (Typical split)
50% (Loose Thrown) 70% (Rough) 85% (Standard Split) 100% (Solid Wood)

Price & Delivery Cost Estimator Optional

$
$
$
Estimated Total Cost
$350.00
Wood: $300.00
Delivery & Stacking: $50.00
Face Cord Equiv: ~$116.67
Calculated Wood Volume 128 ft³ / Cord
Standard Cords
1.00 Full Cords
Gross Volume: 128.00 ft³
Metric Equivalent: 3.62 m³ (Stère)
Solid Wood Content: ~108.8 ft³ (85%)
Face Cords
3.00
@ 16" split
Half Cords
2.00
@ 64 ft³
Ricks / 1/4
4.00
@ 32 ft³
Front View Stack Diagram 8.0' L × 4.0' H
Split round logs ~32 visible logs

Saved Stack Comparisons 0

Save multiple wood stacks to compare volume, cord fractions, and prices.

No saved stacks yet

Adjust dimensions and click "Save Stack Calculation" above to compare multiple piles.

Complete Calculation Suite

Specialized Firewood Calculators & Tools

Choose from our suite of precision calculators for accurate timber measurements, conversions, and delivery planning.

128 ft³ Standard

Full Cord Calculator

Standard 128 cu ft cord calculator with 3D stack visualizer, fraction converter, and cost estimator.

Currently Active Tool
Single Row

Face Cord Calculator

Calculate exact face cords for 12, 16, 18, and 24-inch log lengths and compare against full cords.

Bulk / Dumped

Loose Cord Calculator

Convert dumped, tossed, or trailer-delivered bulk firewood into tightly stacked cord volume.

Multi-Unit

Cord to Cubic Feet Converter

Two-way converter between cords, cubic feet (ft³), cubic meters (m³ / stère), and ricks.

Lbs & Tons

Cord Weight Calculator

Estimate green and seasoned wood weight by species (Oak, Maple, Pine) with truck payload warnings.

32 ft³ Rick

Quarter Cord (1/4) Calculator

Calculate 32 cu ft stack dimensions, rick equivalents, and check pickup truck bed capacity fit.

Measurement Methodology

Hur Beräkning av Vedmått Fungerar

Understanding legal cord dimensions, stacking density, and volume formulas

1

Measure Dimensions

Measure the height, width, and log length of your firewood stack in feet or meters.

2

Compute Gross Volume

Calculate cubic volume (L × W × H) to establish gross stacked volume.

3

Convert to Cords

Divide by 128 cu ft (or 3.624 m³) to determine total cords and heating value.

Standard Conversion Benchmarks

Standard Firewood Cord Reference Chart

Comparison of official firewood measurement units, stack dimensions, cubic volume, and estimated heating duration.

Measurement Unit Dimensions (H × W × L) Cubic Feet Cubic Meters Cord Equivalent
Full Standard Cord Popular
Official Legal Standard
4 ft × 4 ft × 8 ft
1.22 m × 1.22 m × 2.44 m
128 ft³ 3.62 m³ (Stère) 6–10 weeks (Full Winter Primary Heat)
Half Cord
Standard Half Stack
4 ft × 4 ft × 4 ft
1.22 m × 1.22 m × 1.22 m
64 ft³ 1.81 m³ 3–5 weeks (Moderate Supplemental Heat)
Face Cord (16" Logs) Popular
Most Common Retail Unit
4 ft × 1.33 ft × 8 ft
1.22 m × 0.40 m × 2.44 m
42.67 ft³ 1.21 m³ 2–3 weeks (Fireplace & Evening Use)
Quarter Cord / Rick
Small Batch / Campfire
4 ft × 2 ft × 4 ft (or 1/4 Cord)
1.22 m × 0.61 m × 1.22 m
32 ft³ 0.91 m³ 1–2 weeks (Occasional Weekend Burning)
Double Cord
Bulk Winter Supply
4 ft × 8 ft × 8 ft (or 4 × 4 × 16 ft)
1.22 m × 2.44 m × 2.44 m
256 ft³ 7.25 m³ Entire Season (Large Rural Home)

• Note: Solid wood content ranges from 75–90 cu ft per standard cord due to natural air spaces between split logs.

Test your custom stack in the calculator →
Domain Knowledge & Taxonomy

Key Firewood Measurement & Heating Entities

Authoritative physical definitions, volumetric conversion baselines, and thermal energy metrics.

Legal Standard Unit 4 ft × 4 ft × 8 ft
Full Cord (128 ft³ / 3.62 m³)
The legal standard unit of stacked firewood in North America, legally defined by NIST Handbook 130 and the USDA Forest Service as 128 gross cubic feet (3.62 m³ in metric stère). When split logs are tightly stacked, a full cord typically yields between 75 and 90 ft³ of solid wood volume, with the remaining 38 to 53 ft³ consisting of interstitial airspace necessary for airflow.
Retail Fraction Unit 4 ft × 1.33 ft (16") × 8 ft
Face Cord / Rick (42.67 ft³)
A widely used retail and residential measurement representing a single vertical tier of firewood measuring 4 feet high by 8 feet long, cut to standard 16-inch stove lengths (1.33 ft). One face cord yields approximately 42.67 cubic feet—precisely one-third (1/3) of a standard 128 ft³ full cord. In regional markets, this volume is also referred to as a "rick" or "fireplace cord".
Fuel Density & Coals 24.0–28.0+ Million BTU/Cord
Hardwood Species (High BTU Yield)
Dense, slow-growing deciduous trees with compact cellular vascular systems. Premier heating hardwoods—including White Oak (25.7M BTU), Sugar Maple (24.0M BTU), and Shagbark Hickory (27.7M BTU)—generate sustained, high-temperature heat output and long-lasting ember beds that sustain overnight home heating with minimal reloading.
Fast Ignition & Flame 15.0–20.0 Million BTU/Cord
Softwood Species (Kindling & Shoulder Seasons)
Coniferous gymnosperms including White Pine (15.9M BTU), Douglas Fir (20.6M BTU), and Spruce. Softwoods feature lower specific gravity and resinous fibers that ignite rapidly and burn with brisk flame. They are ideal for lighting kindling, rapid stove warm-up, and moderate autumn or spring temperatures where intense long-burning coal beds are unnecessary.
Thermal Energy Metric 1 BTU = Heat to raise 1 lb H₂O by 1°F
British Thermal Unit (BTU Heat Output)
The international physical standard used to quantify the chemical heat energy released during wood combustion. In firewood calculations, heat output is evaluated in Millions of BTUs (MBTU) per air-dried cord at 20% moisture content, directly reflecting dry wood density rather than species volume alone.
Combustion Efficiency Standard Moisture Content < 20% (Dry Basis)
Seasoned Wood (<20% Moisture Content)
Firewood that has been split, elevated off damp ground, and naturally seasoned in breezy sun exposure for 6 to 24 months. Burning wood with under 20% moisture ensures heat is radiated into living spaces rather than wasted evaporating internal sap water, reducing creosote condensation and chimney fire hazards by over 90% in accordance with CSIA and NFPA 211 guidelines.
Heating Appliance Efficiency EPA Certified 70–80%+ Efficiency
Wood-Burning Stove (EPA Clean Burn)
Modern airtight wood-burning stoves and fireplace inserts engineered with secondary combustion air tubes or catalytic combustors. Operating an EPA-certified stove with properly measured, dry hardwood produces minimal particulate emissions, delivers clean burn cycles, and extracts maximum BTUs per cord compared to open masonry hearths.
Diagnostic Testing Tool Electrical Resistance Pin Gauge
Digital Pin Moisture Meter
The authoritative diagnostic tool recommended by the EPA Burn Wise initiative and USDA Forest Service. By penetrating two metal probe pins into the freshly split center grain of a log, home heating operators verify whether wood has achieved the safe threshold of under 20% moisture content prior to burning.
Processing & Curing Tool 20–35 Ton Splitting Force
Hydraulic Log Splitter
Heavy-duty machinery that divides round logs into triangular or rectangular splits. Because intact tree bark acts as a natural water-repellent vapor barrier, mechanical log splitting multiplies exposed surface area by up to 400%, allowing internal sap moisture to evaporate rapidly during summer seasoning.
Expert Answers

Frequently Asked Questions

Everything you need to know about firewood cord measurements, legal definitions, and stacking

What is a standard cord of firewood?

A standard cord of firewood is a legally defined volume of tightly stacked wood measuring 128 cubic feet (3.62 m³). The traditional stack dimensions are 4 feet high, 4 feet deep (or log length), and 8 feet long (4' × 4' × 8').

What is the difference between a full cord and a face cord?

A full standard cord measures 128 cubic feet regardless of log length. A face cord (also known as a rick) is a single stack that is 4 feet high and 8 feet long, but only as deep as the cut log length (typically 16 inches). A 16-inch face cord is approximately 1/3 of a full cord (about 42.6 cubic feet).

How many cords of firewood fit in a pickup truck bed?

A standard 8-foot long truck bed holds roughly 1/2 of a cord when stacked neatly level with the bed rails, or about 1/3 cord if loosely thrown. A 6.5-foot short bed holds approximately 1/3 cord stacked or 1/4 cord thrown.

How much solid wood is actually in a 128 cubic foot cord?

Because firewood has natural curvature and air gaps between split logs, a cord of 128 cubic feet typically contains between 75 and 90 cubic feet of actual solid wood, with the remainder being necessary air space for airflow and drying.

How do I calculate cords from custom stack dimensions?

Multiply the length × width × height in feet to get the total cubic feet, then divide by 128. For example, a stack 12 feet long, 4 feet wide, and 5 feet high is 240 cubic feet. 240 ÷ 128 = 1.875 standard cords.